- Polyester/Carbon
- Soft Hypolon sole
- Autoclavable
- White or blue
The flat Overshoes are washable and equipped with rubber and envelope flap. These have a soft sole.
Material & Properties
- Material: 98 % polyester / 2 % carbon
- Weight: 118 g/m²
- ISO 4 - 8
- EU GMP A - C /US FED Std 10 - 100,000
- Type of antistatic yarn: Negastat P210
- Fabric: Twill 3/2
- Pattern: Plaid 5mm * 5mm
- Sterilization: Steam - Gamma
- Breathability ISO 9237-2:1995: 18.10 l/m².s
- Water tightness DIN EN ISO 11092:2014 Ret: 2,71 m²Pa/W
- Tear strength ISO 13934/1:2013: warp 830 N / weft 1500 N
- Abrasion resistance ISO 12947/2:1998: > 100,000 cycles
- Decay time EN 1149-3: 0.01 sec
- Surface resistance EN 1149-1: 10 exp6 Ohm
- Particle retention: 0.3 µm = 98%, 0.5 µm = 98%, 5.0 µm = 98%
The reusable garment is made of lightweight micropolyester fabric.
1. maximum washing machine load : 60 %.
2. washing chemicals: anionic / non-ionic, preferably pure anionic agents with good dispersing properties.
3. maximum pH: 8 - 8.5. close zipper and push buttons before washing.
4. prewash: maximum 35°C - 10 minutes
5. main wash: maximum 60°C - 15 minutes
6. cool down 1°C per minute up to 50°C to avoid wrinkles
7. rinse ( 2 x ) and neutralize with 1 cc/kg acetic acid 80%, 10 min at 40°C.
8. last rinse: we recommend an antibacterial and antistatic detergent.
9. dry gently and slowly.
10. Tumble dry at maximum 85°C.
APPLICATION
For optimal effectiveness: try to wear clothes as closed as possible and try to avoid air holes at the neck. Air formation in the clothing (blow-up effect) must be avoided. Have your cleanroom clothing decontaminated and washed in time to avoid contamination in the cleanroom. Cleanroom clothing is not water repellent and quickly absorbs water and chemicals. Small holes and tears should be repaired (patched) as soon as possible. Cleanroom clothing should not come into contact with solvents, chemicals, disinfectants and stain removers
MAINTENANCE
The washing frequency depends on the working environment (microelectronics - pharmaceutical ...) and working conditions. The cleanroom garments should be washed in a cleanroom laundry. The maximum washing temperature is 60°C - Do not iron! The addition of chlorine is prohibited in the washing process. A thorough rinsing and neutralization. A PH- value between 5.5 and 6 should be achieved. If dry cleaning is required: only with perchloroethylene. When drying in a dryer, a low speed is recommended. Maximum shrinkage: less than 3%.
Packaging
- 1 pair
ISO Klasse: | 4 |
---|---|
Disposable/Reusable: | Reusable |
Material: | Karbon, Polyester |