Isolator boxes and so-called RABS (restricted access barrier systems) are gaining importance in various industries, from pharmaceutical and electronics manufacturing to food processing and nuclear applications.
They shield the product from people and the environment and offer people and the environment protection from hazards and critical materials.
The controlled, regulated work environment inside the box is isolated from the outside world by a barrier and is usually sterile or clean. The atmosphere can be precisely adjusted in terms of air pressure, humidity and other parameters to meet the specific requirements of the application. Every material and every application requires a specific isolator glove, which must be tailored to the needs of the task in the isolator box.
Mechanical properties, temperature and chemical resistance of the material, the fit and the sterilization types of the isolator gloves are criteria that should be considered when making a suitable selection.
They shield the product from people and the environment and offer people and the environment protection from hazards and critical materials.
The controlled, regulated work environment inside the box is isolated from the outside world by a barrier and is usually sterile or clean. The atmosphere can be precisely adjusted in terms of air pressure, humidity and other parameters to meet the specific requirements of the application. Every material and every application requires a specific isolator glove, which must be tailored to the needs of the task in the isolator box.
Mechanical properties, temperature and chemical resistance of the material, the fit and the sterilization types of the isolator gloves are criteria that should be considered when making a suitable selection.
Filter
–
PU:
1 piece
BioClean validated sterile "RABS and isolator gloves" are made from nitrile with incredibly low particle content and excellent ESD properties. Designed for use in product contact areas, the GGL series gloves are fully validated for sterility with a SAL (Sterility Assurance Level) of 10-6 and are available in a range of port sizes.
Material & Properties
Material: Nitrile
Length: 840 mm
Port size:
Normal Grip
ISO 4
EU GMP A
Sterile
Packaging
One per sealed inner PE bag
one inner bag per sealed second inner PE bag
One second inner bag per sealed outer PE bag
20 outer bags per lined inner white Correx polyethylene box (20 pieces)
PU:
Carton with 20 pairs
BioClean "RABS and insulator gloves" are made of made of nitrile and are characterised by very low particle content and Excellent ESD properties. Designed for use in product product-contact areas, our CGL series gloves are processed and packaged in the cleanroom and are available in a range of port sizes.
Material & Properties
Material: Nitrile
Length: 840 mm
normal grip
Port size: 203-254 mm
Packaging
One per sealed inner PE bag
one inner bag per sealed second inner PE bag
one second inner bag per sealed outer PE bag
20 outer bags per lined inner white Correx polyethylene box (20 pieces)
PU:
Carton with 20 pairs
BioClean validated sterile "RABS and isolator gloves" are made from nitrile with incredibly low particle content and excellent ESD properties. Designed for use in product contact areas, the GGL series gloves are fully validated for sterility with a SAL (Sterility Assurance Level) of 10-6 and are available in a range of port sizes.
Material & Properties
Material: Nitrile
Length: 840 mm
Port size: 305-356 mm
Normal Grip
ISO 4
EU GMP A
Sterile
Packaging
One per sealed inner PE bag
one inner bag per sealed second inner PE bag
One second inner bag per sealed outer PE bag
20 outer bags per lined inner white Correx polyethylene box (20 pieces)
PU:
Carton with 20 pairs
The "RABS/Isolator Arm Cuff GSG10NIT80" is a material-pure, sterile arm cuff/glove system consisting of an arm cuff made of nitrile and an anatomically shaped PCP special glove (BioClean BPZS) size 8 attached with a channel and O-ring, anatomically shaped PCP special glove (BioClean BPZS) size 8. Available in pairs in single packs.
Material & Properties
Material: nitrile, neoprene
Colour: White
Sterile
Tested in accordance with ASTM D6978-05 for the
Handling of cytostatic drugs.
Extremely clean outer surface for effective product protection
Fully inspected and tested (before cutting) for air tightness
Suitable for port sizes 254 mm to 304 mm
Areas of application
Pharmaceutical production
Laboratory research and development
Raw material preparation
Biotechnology manufacturing
Sterilisation department
Semiconductor production
Packaging
1 arm cuff/triple bag, including size 8 PCP glove (with L or R marking) and channel/O-ring unit
Packed in pairs: 2 triple bagged arm cuffs/glove/ring unit per system; 10 systems/white Correx box
2 Correx boxes (20 systems)/white Correx outer box
PU:
1 piece
BioClean validated sterile "RABS and isolator gloves" are made from nitrile with incredibly low particle content and excellent ESD properties. Designed for use in product contact areas, the GGL series gloves are fully validated for sterility with a SAL (Sterility Assurance Level) of 10-6 and are available in a range of port sizes.
Material & Properties
Material: Nitrile
Length: 840 mm
Port size: 203-254 mm
Normal Grip
ISO 4
EU GMP A
Sterile
Packaging
One per sealed inner PE bag
One inner bag per sealed second inner PE bag
One second inner bag per sealed outer PE bag
20 outer bags per lined inner white Correx polyethylene box (20 pieces)
PU:
Carton with 20 pairs
The "RABS/Isolator Arm Cuff GSG10NIT85" is a material-pure, sterile arm cuff/glove system consisting of an arm cuff made of nitrile and an anatomically shaped PCP special glove (BioClean BPZS) size 8,5 attached with a channel and O-ring. Available in pairs in single packs.
Material & Properties
Material: nitrile, neoprene
Colour: White
Sterile
Tested in accordance with ASTM D6978-05 for the
Handling of cytostatic drugs.
Extremely clean outer surface for effective product protection
Fully inspected and tested (before cutting) for air tightness
Suitable for port sizes 254 mm to 304 mm
Areas of application
Pharmaceutical production
Laboratory research and development
Raw material preparation
Biotechnology manufacturing
Sterilisation department
Semiconductor production
Packaging
1 arm cuff/triple bag, including size 8,5 PCP glove (with L or R marking) and channel/O-ring unit
Packed in pairs: 2 triple bagged arm cuffs/glove/ring unit per system; 10 systems/white Correx box
2 Correx boxes (20 systems)/white Correx outer box